Trimax Venture Sdn Bhd (TV) is in the business of supplying of electrical products and providing technical consultancy for generation, transmission, distribution and customer installations in the Malaysian Electricity Supply Industry (MESI).
REG-D | REG-DA |
---|---|
Voltage Control System can be created by adding further options or devices | Configurable Hardware with various options |
REG-D & REG-DA |
---|
Allows both very simple and highly complex measurement, control and regulation tasks for tapped transformers. Alongside its basic functions, the REG-D(A) voltage regulator can also be used as a transducer, recorder, statistical unit, parallel control device and transformer monitor as per IEC 60354 or IEC 60076. |
Limit value monitoring, parallel operation with ParaGramer, current influence, detection of creeping network failures. |
Expandable by customer specific programming. |
SCADA Protocols: IEC 61850 inkl. GOOSE and Sampled Values, IEC 60870-5-101/103/104, Modbus. |
Software : AEToolbox |
REG-D | REG-DA |
---|---|
Various Designs 19” plug-in module, surface-mounted and panel-mounted housing |
Metal Housing wall mounting housing, Panel mounting housing and din-rail mounting |
Unique Flexibility Our AVR offers a flexibly expandable number of inputs and outputs, a wide range of applications through software features, and free programmability. |
The Right Control Protocol for Every Application The following protocols are available: IEC 60870-5-101/103/104,IEC 61850 (Server, Client, GOOSE, 9-2 Sampled values), DNP 3.0 via Ethernet, DNP 3.0, Profibus DP, MODBUS RTU, SPABUS, LON (on request) |
All Necessary Functions in a Single Device The functional scope of our controller is unique. The control of 3-winding transformers, of phase-shifting transformers, of transformer banks and of compensation reactors as well as transformer monitoring is all possible with only one device and one firmware. |
Parallel Operation With Up to 15 Transformer |
Sr No | Application | Ordering Code |
---|---|---|
1A | Conventional | REGSys REG-DA B0 I0 H0 F1 M1 S1 T0 K1 E00 D0 C00 R1 XW00 G2 |
1B | Digital Substation | REGSys REG-DA B0 I0 H0 F1 M1 S1 T0 K1 E00 D0 C00 R1 XW96.1 G2 A2 |
Sr No | Application | Ordering Code |
---|---|---|
2A | Conventional | REGSys REG-DA B0 I0 H0 F1 M1 S1 T0 K1 E00 D0 C92 R1 XW00 G2 A2 |
2B | Digital Substation | REGSys REG-DA B0 I0 H0 F1 M1 S1 T0 K1 E00 D0 C92 R1 XW96.1 G2 A2 |
Application | |
---|---|
PQI – DA SMART (THE FIX-INSTALLED POWER QUALITY ALLROUNDER) |
|
PQI – DE (THE FIX-INSTALLED TOOL FOR POWER QUALITY EXPERTS) |
|
PQI – DA (THE COMPACT DEVICE) |
|
PQI –D (THE FLEXIBLE) |
|
PQ-BOX 50 (UNIVERSAL POWER QUALITY analyser) |
PQ-BOX 150 (POWER QUALITY ALL-ROUNDER) |
PQ-BOX 200 (TOOL FOR THE EXPERT) |
PQ-BOX 300 (HIGH FREQUENCY POWER QUALITY TOOL) |
|
---|---|---|---|---|
SAMPLING FREQUENCY CURRENT | 20.48 KHz | 20.48 KHz | 40.96 KHz | 40.96 KHz |
SAMPLING FREQUENCY TRANSIENT MEASUREMENT | - | - | Up to 4 MHz | 409.60 KHz |
INPUT VOLTAGE (RESOLUTION) | 4(16-bit) | 4(24-bit) | 4(24-bit) | 4(24-bit) |
INPUT CURRENT (RESOLUTION) | 4(16-bit) | 4(24-bit) | 5(24-bit) | 5(24-bit) |
BINARY INPUT | - | . | . | . |
MEMORY SIZE | 1GB | 4GB (32) | 4GB (32) | 8GB (32) |
BATTERY OPERATING TIME | 1.5h | 4.0h | 4.0h | 3.5h |